Premises Standard Schedule 1 Part E3
What is the Access to Premises Standards | Disability Buildings Standard | Disability Discrimination Act 1992 | DDA Consultants
Part E3 Lift installations
| EP3.4 |
Performance Requirement
When a passenger lift is provided in a building required to be accessible, it must be suitable for use by people with a disability.
|
|
|
| E3.0 |
Deemed to Satisfy Provisions
Performance Requirement EP3.4 is satisfied by complying with:
(a) clause E3.6; and
(b) for public transport buildings, Part H2.
|
|
|
| E3.6 |
Passenger lifts
In an accessible building, every passenger lift must:
(a) be one of the lift types identified in Table E3.6 (a), subject to the limitations on use specified in the table; and
(b) have accessible features in accordance with Table E3.6 (b); and
(c) not rely on a constant pressure device for its operation if the lift car is fully enclosed. |
|
|
Table E3.6 (a) Limitations on use of types of passenger lifts
| Lift type |
Limitations on use |
| AS 1735.1 Appendix A |
No limitation |
| AS 1735.2 electric passenger lift |
No limitation |
| AS 1735.3 electrohydraulic lift |
No limitation |
| AS 1735.7 stairway platform lift |
Must not:
(a) be used to serve a space in a building accommodating more than 100 persons calculated according to clause D1.13 of the BCA; or
(b) be used in a high traffic public use area such as a theatre, cinema, auditorium, transport interchange, shopping centre or the like; or
(c) connect more than 2 storeys; or
(d) where more than 1 stairway lift is installed, serve more than 2 consecutive storeys; or
(e) when in the folded position, encroach on the minimum width of a stairway required by clause D1.6 of the BCA. |
| AS 1735.8 inclined lift |
No limitation |
| AS 1735.14 low rise platform lift |
Must not travel more than 1 000 mm |
| AS 1735.15 lift for persons with limited mobility |
Must not:
(a) for an enclosed type, travel more than 4m; or
(b) for an unenclosed type, travel more than 2m; or
(c) be used in high traffic public use areas in buildings such as a theatre, cinema, auditorium, transport interchange, shopping complex or the like |
| AS 1735.16 lift for persons with limited mobility |
Must not travel more than 12 m |
Table E3.6 (b) Application of features to passenger lifts
| Feature |
Application |
| Handrail complying with the provisions for a mandatory handrail in AS 1735.12 |
All lifts except:
(a) a stairway platform lift complying with AS 1735.7; and
(b) a low rise platform lift complying with AS 1735.14 |
| Lift floor dimension of not less than 1 400 mm x 1 600 mm |
All lifts which travel more than 12 m |
| Lift floor dimensions of not less than 1 100 mm x 1 400 mm |
All lifts which travel not more than 12 m except a stairway platform lift complying with AS 1735.7 |
| Lift floor dimensions of not less than 810 mm x 1 200 mm |
A stairway platform lift complying with AS 1735.7 |
| Minimum clear door opening complying with AS 1735.12 |
All lifts except a stairway platform lift complying with AS 1735.7 |
| Passenger protection system complying with AS 1735.12 |
All lifts with a power operated door |
| Lift landing doors at the upper landing |
All lifts except a stairway platform lift complying with AS 1735.7 |
| Lift car and landing control buttons complying with AS 1735.12 |
All lifts except:
(a) a stairway platform lift complying with AS 1735.7; and
(b) a low rise platform lift complying with AS 1735.14 |
| Lighting in accordance with AS 1735.12 |
All enclosed lift cars |
(a) Automatic audible information within the lift car to identify the level each time the car stops; and
(b) audible and visual indication at each lift landing to indicate the arrival of the lift car; and
(c) audible information and audible indication required by (a) and (b) is to be provided in a range of between 20–80 dbA at a maximum frequency of 1 500 Hz |
All lifts serving more than 2 levels |
| Emergency hands free communication, including a button that alerts a call centre of a problem and a light to signal that the call has been received |
All lifts except a stairway platform lift complying with AS 1735.7 |